AEGIS SGR Installation and Selection
Selecting the Right Size SGR For Your Motor
-
Step 1: Measure Shaft diameter at a point 1/8" (3mm) from motor end bell.
-
Step 2: To select the correct SGR part number, refer to SGR size chart provided.
Installation
For proper operation and optimum performance, install AEGIS SGR™ so that:
-
The conductive MicroFibers. touch the shaft for effective shaft grounding.
-
The aluminum brush holder frame extends out from the motor end bell approximately 0.28" (7mm).
-
The aluminum brush holder frame has even clearance around the shaft.
-
Slide SGR over motor shaft and position for even clearance around the shaft.
-
Drill two 1/4" deep holes into motor end bell and tap each with a 6-32 thread or M# thread.
-