Quality-Dependability-Value   
MaxMotion Home
Warranty
AC Motors
Cast Iron T Frame
Technical Data Tables
Connection Diagrams
Bearing Tables
Rolled Steel T Frame - ODP
Technical Data Tables
Connection Diagrams
Bearing Tables
Rolled Steel T Frame - TEFC
Technical Data Tables
Connection Diagrams
Bearing Tables
Stainless Steel Motors
Selection Table
Connection Diagrams
Dimensions
All-in-One, 56C Frame, Single phase
Connection Diagrams
All-in-One, 56C Frame, Three phase
Connection Diagrams
General Purpose, 3 Phase, ODP, Rigid Base
Connection Diagrams
Belted Fan, Single Phase, Split Phase, ODP
Connection Diagrams
Belted Fan, Single Phase, Capacitor Start, ODP
Connection Diagrams
DC Motors
Technical Data Tables
SCR Controls
Technical Data Tables
Drive Line and Load Reactors
AC Line Reactors - 3 % Impedence
AC Line Reactors - 5 % Impedence
AEGIS SGRs
Selection and Installation
NEMA Part Numbers
Metric Part Numbers
About Shaft Current
Frequently Asked Questions
Motor Slide and Transition Bases
Selection Charts
How to Contact Us
Search

SCR Controls


125E Series
Variable Speed DC Control

Click for a close up view of SCR Control 125E
In a rugged, light-weight
aluminum enclosure that
provides NEMA 1 protection

Click here to see selection
and specifications

  • Dual Voltage 120/240 @ 50/60Hz
  • Adjustable HP settings
  • Barrier Terminal Strip
  • Full wave bridge supply
  • 1% speed regulation with armature feedback, 1/2% with Tach. Feedback
  • Adjustable Min Speed (0-30% of Max)
  • Line Voltage Compensation
  • Adjustable Current Limit
  • Adjustable IR Compensation
  • Overload capacity: 200% for one minute
  • Transient Voltage protection
  • Shunt Field supply 1 amp max, 100V for 120VAC, 200V for 240VAC
  • 15A fuse in-line with AC input
  • Temperature -10° to +45° C
  • AC Input Voltage +/-10% Rated Line Voltage
  • Input Frequency 50/60Hz
  • 50:1 Speed range
  • CSA & cUL & CE compliance on control

253E Series
Variable Speed DC Control

Click for a close up view of SCR Control 253E
NEMA 4/12 enclosure for
harsh environments and
washdown conditions

Click here to see selection
and specifications

  • Dual Voltage 120/240 @ 50/60Hz
  • Adjustable HP settings
  • Barrier Terminal Strip
  • Full wave bridge supply
  • 1% speed regulation with armature feedback, 1/2% with Tach. Feedback
  • Adjustable Min Speed (0-30% of Max)
  • Adjustable Max speed (66 to 110% of base speed)
  • Line Voltage Compensation
  • Adjustable IR Compensation
  • Adjustable Current Limit to 15 Amps
  • Power On/Off Switch
  • Adustable linear Acceleration
  • Overload capacity: 150% for one minute
  • Transient Voltage protection
  • Shunt Field supply 1 amp max, 100V for 120VAC, 200V for 240VAC
  • Inhibit Circuit - Start/Stop without breaking AC lines
  • Temperature -10° to +45° C
  • Remote Start/Stop
  • AC line fuse
  • 50:1 Speed range
  • Voltage Following Mode or DC tach follower
  • DC Tach Feedback
  • C.S.A. Certified, UL listed